Phone: (+33) 625 16 20 71 - Sunday to Friday contact@alliancemedicalfrance.fr

Olympus Duodénovidéoscope TJF-160VF

Olympus

Duodénovidéoscope TJF-160VF

Starting from
8 725 .00 €

Olympus TJF-160VF EVIS EXERA video duodenoscope with a 4.2 mm channel, 1240 mm working length, 100° field of view and 5° backward-oblique viewing for ERCP procedures.

Olympus TJF-160VF – Refurbished Video Duodenoscope

The Olympus TJF-160VF is a video duodenoscope designed for ERCP procedures requiring precise guidance and effective instrument control. It combines a large working channel, multidirectional angulation, and a guidewire retention system to facilitate accessory exchanges during biliary and pancreatic interventions.

Guidewire Retention System

The TJF-160VF incorporates a V-groove forceps elevator designed to maintain the guidewire in position during instrument exchanges. This configuration helps preserve guidewire positioning throughout the different stages of therapeutic procedures involving the biliary and pancreatic ducts.

Imaging and Visualization

The optical system provides a 100° field of view with a 5° rearward oblique viewing direction. This configuration supports visualization of the papillary region and facilitates endoscope positioning during biliary and pancreatic procedures.

Design and Maneuverability

The video duodenoscope features an ergonomic control handle with an organized control layout designed for smooth operation. Its 13.2 mm insertion tube diameter, combined with a 4.2 mm working channel, allows the introduction and manipulation of compatible accessories used during ERCP procedures.

The multidirectional angulation of the distal section allows precise orientation toward the Vater's papilla and facilitates positioning within the biliary and pancreatic anatomy.

Compatibility and Identification

The TJF-160VF is designed for use with compatible video endoscopy systems, allowing integration into existing endoscopy setups.

An endoscope identification function also supports management and tracking of device-related information within a hospital environment.

The Olympus TJF-160VF combines an ERCP-oriented configuration, a 4.2 mm working channel, a wide range of angulation, and a guidewire retention system. It is designed to support biliary and pancreatic endoscopic procedures requiring precise instrument control.

Quick delivery worldwide
All our equipment is rigorously tested to ensure its quality and compliance with safety standards.
Download brochure

Olympus TJF-160VF – Refurbished Video Duodenoscope

The Olympus TJF-160VF is a video duodenoscope designed for ERCP procedures requiring precise guidance and effective instrument control. It combines a large working channel, multidirectional angulation, and a guidewire retention system to facilitate accessory exchanges during biliary and pancreatic interventions.

Guidewire Retention System

The TJF-160VF incorporates a V-groove forceps elevator designed to maintain the guidewire in position during instrument exchanges. This configuration helps preserve guidewire positioning throughout the different stages of therapeutic procedures involving the biliary and pancreatic ducts.

Imaging and Visualization

The optical system provides a 100° field of view with a 5° rearward oblique viewing direction. This configuration supports visualization of the papillary region and facilitates endoscope positioning during biliary and pancreatic procedures.

Design and Maneuverability

The video duodenoscope features an ergonomic control handle with an organized control layout designed for smooth operation. Its 13.2 mm insertion tube diameter, combined with a 4.2 mm working channel, allows the introduction and manipulation of compatible accessories used during ERCP procedures.

The multidirectional angulation of the distal section allows precise orientation toward the Vater's papilla and facilitates positioning within the biliary and pancreatic anatomy.

Compatibility and Identification

The TJF-160VF is designed for use with compatible video endoscopy systems, allowing integration into existing endoscopy setups.

An endoscope identification function also supports management and tracking of device-related information within a hospital environment.

The Olympus TJF-160VF combines an ERCP-oriented configuration, a 4.2 mm working channel, a wide range of angulation, and a guidewire retention system. It is designed to support biliary and pancreatic endoscopic procedures requiring precise instrument control.

  • Elevator: Features a V-shaped groove designed to hold and stabilize the guidewire.
  • Distal Angulation: Enables precise orientation of the distal tip in four directions.
  • Ergonomic Controls: The handle provides easy access to the main controls for convenient operation.
  • Instrument Channel: Compatible with devices and accessories designed for ERCP procedures.
  • Scope ID: Integrated identification function facilitates device identification and tracking.
  • System Compatibility: Designed for use with suitable compatible video platforms.
Longueur utile :
1 240 mm
Diamètre du tube d’insertion :
11,3 mm
Diamètre distal :
13,2 mm
Direction de vue :
oblique arrière à 5°
Champ de vision :
100°
Diamètre interne du canal opérateur :
4,2 mm
  • MH-553 – Water-resistant cap
  • MAJ-1119 – Water-resistant cap chain
  • MB-358 – Biopsy valve
  • MH-443 – Suction valve
  • MH-438 – Air/water valve
  • MB-142 – Mouthpiece