Olympus Source lumineuse xénon d'endoscopie CLV-S40Pro

Olympus

Source lumineuse xénon d'endoscopie CLV-S40Pro

Starting from
905 .00 €

Olympus CLV-S40Pro VISERA Pro xenon light source with a 300 W lamp, automatic brightness adjustment and NBI support, designed for high-intensity endoscopic illumination.

Olympus CLV-S40Pro – Light Source

The Olympus CLV-S40Pro is a light source designed to centralize essential illumination controls during endoscopic examinations. Its front panel provides convenient access to the system's main functions.

Illumination Control

The control panel provides functions for powering on the unit, activating the lamp, adjusting light intensity, and switching between automatic and manual modes. Status indicators provide a direct view of the system's operating condition.

When used with a compatible VISERA Pro video processor and videoscope, light intensity can be regulated automatically to maintain stable illumination despite variations in the distance between the endoscope and the area being examined.

When used with a fiberscope, light intensity is adjusted manually. The high-intensity mode allows the illumination level to be increased when the endoscope and light guide being used are compatible.

Connectivity and Integration

The rear panel provides the main interfaces required for integration into an operating-room environment:

  • AC power connection
  • OTV connection
  • System terminal
  • Footswitch connection
  • Equipotential terminal

Lamp Monitoring

The lamp operating-hour indicator helps monitor lamp usage and anticipate replacement. The various indicators on the control panel also provide immediate monitoring of active functions during operation.

Key Features

  • Olympus light source for endoscopic applications
  • Automatic or manual light intensity adjustment
  • High-intensity mode with compatible equipment
  • Compatible with VISERA Pro and compatible videoscopes
  • Manual adjustment when used with fiberscopes
  • Lamp operating-hour indicator
  • Connectivity designed for operating-room environments
  • Compatible footswitch connection
Quick delivery worldwide
All our equipment is rigorously tested to ensure its quality and compliance with safety standards.
Download brochure

Olympus CLV-S40Pro – Light Source

The Olympus CLV-S40Pro is a light source designed to centralize essential illumination controls during endoscopic examinations. Its front panel provides convenient access to the system's main functions.

Illumination Control

The control panel provides functions for powering on the unit, activating the lamp, adjusting light intensity, and switching between automatic and manual modes. Status indicators provide a direct view of the system's operating condition.

When used with a compatible VISERA Pro video processor and videoscope, light intensity can be regulated automatically to maintain stable illumination despite variations in the distance between the endoscope and the area being examined.

When used with a fiberscope, light intensity is adjusted manually. The high-intensity mode allows the illumination level to be increased when the endoscope and light guide being used are compatible.

Connectivity and Integration

The rear panel provides the main interfaces required for integration into an operating-room environment:

  • AC power connection
  • OTV connection
  • System terminal
  • Footswitch connection
  • Equipotential terminal

Lamp Monitoring

The lamp operating-hour indicator helps monitor lamp usage and anticipate replacement. The various indicators on the control panel also provide immediate monitoring of active functions during operation.

Key Features

  • Olympus light source for endoscopic applications
  • Automatic or manual light intensity adjustment
  • High-intensity mode with compatible equipment
  • Compatible with VISERA Pro and compatible videoscopes
  • Manual adjustment when used with fiberscopes
  • Lamp operating-hour indicator
  • Connectivity designed for operating-room environments
  • Compatible footswitch connection
  • Dedicated Power-On: Provides direct control of the examination lamp.
  • Automatic Mode: Automatically modulates light intensity through the video system.
  • Manual Mode: Allows light intensity to be adjusted in steps from the front panel.
  • High Intensity: Provides a temporary boost in light output for more precise observation.
  • Filtered Observation: Allows switching to NBI or PDD modes according to examination requirements.
  • Backup Relay: Maintains illumination in the event of a failure of the main system.
Lampe principale :
arc court au xénon sans ozone, 300 W
Poids :
14,9 kg
Dimensions :
383 × 162 × 536 mm
Fusibles :
8 A, 250 V, Ø 5 × 20 mm
Alimentation :
100–240 V CA, 50/60 Hz, 500 VA
Environnement :
10–40 °C, 30–85 % HR, 700–1060 hPa
  • MAJ-1411 – Light Source Control Cable
  • MAJ-1391 – Foot Switch
  • MAJ-1429 – PDD Filter
  • MAJ-1205 – Foot Holders
  • MAJ-1412 – Replacement Fuses
  • OTV-S7Pro – VISERA Pro Video Processor