OLYMPUS Olympus CV-100 Video Processor

OLYMPUS

Olympus CV-100 Video Processor

The Olympus CV-100 is an endoscopy video processor with single-plate color chip technology for high-resolution, true color images without break-up. It includes AGC, selectable iris modes, a fast shutter up to 1/250s, and adjustable hue control.

Olympus CV-100 Video Processor

The CV-100 is a video processor built for endoscopy imaging. Its single-plate color chip design produces high-resolution, true color video without the image break-up that can affect older processors.

  • Automatic gain control (AGC): keeps image brightness steady even when the light level drops.
  • Iris mode selection: switches between AVERAGE and PEAK exposure measurement. AVERAGE is the standard setting; PEAK dims the brightest part of the image, which helps with observation of the gastric angle.
  • Fast shutter: runs at 1/60 second for most exams, with a 1/250 second option to reduce blur when the scope or the subject is moving.
  • Hue adjustment level indicator: lets the user fine-tune red and blue for personal preference.
  • Mode selector: choose FIELD mode for movement-free frozen images, or FRAME mode for better vertical resolution when examining small areas.
  • Enhancement selector: three levels of outline/edge enhancement for clearer detail on protruding structures.
  • Sub screen: when turned on, shows a live image in the lower-left corner of the monitor while the main image is frozen.
  • VTR switch: starts and stops recording of the monitor image onto videotape (VTR must be in record-pause mode).
  • Videoprinter release switch: prints the monitor image.
  • Monitor output selector: picks between RGB, Y/C, or NTSC signal output for different monitors and ancillary devices; the Y/C output is meant for S-VHS recorders.
  • Remote switch function display: shows which of the videoscope's four remote switch functions are pre-selected.
  • Record destination selector: routes the image to up to four still-image recording systems.
  • Videoscope cable holder: holds the cable connector securely when it's not attached to the videoscope, so it doesn't get damaged.
Quick delivery worldwide
All our equipment is rigorously tested to ensure its quality and compliance with safety standards.
Download brochure

Olympus CV-100 Video Processor

The CV-100 is a video processor built for endoscopy imaging. Its single-plate color chip design produces high-resolution, true color video without the image break-up that can affect older processors.

  • Automatic gain control (AGC): keeps image brightness steady even when the light level drops.
  • Iris mode selection: switches between AVERAGE and PEAK exposure measurement. AVERAGE is the standard setting; PEAK dims the brightest part of the image, which helps with observation of the gastric angle.
  • Fast shutter: runs at 1/60 second for most exams, with a 1/250 second option to reduce blur when the scope or the subject is moving.
  • Hue adjustment level indicator: lets the user fine-tune red and blue for personal preference.
  • Mode selector: choose FIELD mode for movement-free frozen images, or FRAME mode for better vertical resolution when examining small areas.
  • Enhancement selector: three levels of outline/edge enhancement for clearer detail on protruding structures.
  • Sub screen: when turned on, shows a live image in the lower-left corner of the monitor while the main image is frozen.
  • VTR switch: starts and stops recording of the monitor image onto videotape (VTR must be in record-pause mode).
  • Videoprinter release switch: prints the monitor image.
  • Monitor output selector: picks between RGB, Y/C, or NTSC signal output for different monitors and ancillary devices; the Y/C output is meant for S-VHS recorders.
  • Remote switch function display: shows which of the videoscope's four remote switch functions are pre-selected.
  • Record destination selector: routes the image to up to four still-image recording systems.
  • Videoscope cable holder: holds the cable connector securely when it's not attached to the videoscope, so it doesn't get damaged.

The CV-100 pairs with a specific set of Olympus equipment to form a complete endoscopy tower.

  • Light source: requires an Olympus CLV-U20 or CLV-U40 light source. The light source's pigtail plugs into the "AUX" port on the front of the CLV-U20 to control light adjustment from the processor.
  • Videoscopes: works with standard and big-chip endoscopes, including scopes from the Olympus EVIS 100 series.
  • Monitor: any monitor accepting RGB, Y/C, or NTSC input, selected through the processor's Monitor Output Selector.
  • Video tape recorder (VTR): standard VTRs, or S-VHS recorders via the Y/C output, controlled through the VTR start/stop switch.
  • Video printer: a compatible Olympus, Pentax, or Fujinon video printer, triggered by the Videoprinter Release Switch. Note that printer paper and remote cables are typically sold separately.
  • Still-image recording systems: up to four devices — video image recorder, magnetic disk, videodisk, or digital filter — connected through the Record Destination Selector.

Sourced from the Olympus CV-100 brochure and equipment listings from Soma Technology and 1800Endoscope.com.1 Confirm exact model numbers with your equipment supplier, since light source and scope compatibility can vary by unit configuration and age.