EVIS EXERA II 165 Series — System Overview

The EVIS EXERA II 165 Series is not built around a dedicated CV-165/CLV-165 processor — no such model appears in this brochure. Instead, "165" refers to the generation of videoscopes (GIF Type Q165 and CF Type Q165L/I), which are designed to work with Olympus's existing EVIS EXERA processor line: the CV-160 video processor and its corresponding CLV-160 light source, as well as backward compatibility with the CV-145 and CV-140 generations.

System components

  • Video processor: CV-160 (or CV-145/CV-140 for backward-compatible setups)
  • Light source: paired xenon light source from the same generation (CLV-160)
  • Endoscopy cart with monitor
  • Scopes: GIF Type Q165 (gastroscope) and/or CF Type Q165L/I (colonoscope)

What the 165 scopes bring to the system

When paired with a compatible processor, the 165 Series scopes are what deliver the imaging gains described in the brochure: sharper picture edges, better reproduction of fine capillaries and mucosal texture, and a full-height display mode that fills the monitor's vertical space. Structure enhancement circuitry and automatic iris control further improve contrast and reduce the need for manual light adjustment during a procedure.

Scope ID function

Each 165 Series scope has a built-in memory chip that stores its model number, serial number, and preferred settings. When connected to the processor, this information uploads automatically and the system adjusts accordingly — a convenience for managing multiple scopes in a busy endoscopy suite.

Data and connectivity

  • Built-in PC card slot for storing still images on removable media
  • DV interface (i.LINK) for transferring images to a DV/DVCAM-type VCR or DV-compatible PC
  • Annotation function for adding patient ID, name, scope, date, and comments to images, exportable as HTML without altering originals
  • Index display showing the most recently captured image in the corner of the screen

Compatibility

The system is explicitly compatible with the CV-160, CV-145, and CV-140 processors, and extends backward compatibility to the older EVIS 100, 140, and 145 Series. It supports both gastrointestinal endoscopy and bronchoscopy.

If you have a separate spec sheet naming an actual CV-165/CLV-165 processor, I'd need to see it — this brochure only documents the scopes and their compatibility with the 160/145/140 processor generation.

Quick delivery worldwide
All our equipment is rigorously tested to ensure its quality and compliance with safety standards.
Download brochure

EVIS EXERA II 165 Series — System Overview

The EVIS EXERA II 165 Series is not built around a dedicated CV-165/CLV-165 processor — no such model appears in this brochure. Instead, "165" refers to the generation of videoscopes (GIF Type Q165 and CF Type Q165L/I), which are designed to work with Olympus's existing EVIS EXERA processor line: the CV-160 video processor and its corresponding CLV-160 light source, as well as backward compatibility with the CV-145 and CV-140 generations.

System components

  • Video processor: CV-160 (or CV-145/CV-140 for backward-compatible setups)
  • Light source: paired xenon light source from the same generation (CLV-160)
  • Endoscopy cart with monitor
  • Scopes: GIF Type Q165 (gastroscope) and/or CF Type Q165L/I (colonoscope)

What the 165 scopes bring to the system

When paired with a compatible processor, the 165 Series scopes are what deliver the imaging gains described in the brochure: sharper picture edges, better reproduction of fine capillaries and mucosal texture, and a full-height display mode that fills the monitor's vertical space. Structure enhancement circuitry and automatic iris control further improve contrast and reduce the need for manual light adjustment during a procedure.

Scope ID function

Each 165 Series scope has a built-in memory chip that stores its model number, serial number, and preferred settings. When connected to the processor, this information uploads automatically and the system adjusts accordingly — a convenience for managing multiple scopes in a busy endoscopy suite.

Data and connectivity

  • Built-in PC card slot for storing still images on removable media
  • DV interface (i.LINK) for transferring images to a DV/DVCAM-type VCR or DV-compatible PC
  • Annotation function for adding patient ID, name, scope, date, and comments to images, exportable as HTML without altering originals
  • Index display showing the most recently captured image in the corner of the screen

Compatibility

The system is explicitly compatible with the CV-160, CV-145, and CV-140 processors, and extends backward compatibility to the older EVIS 100, 140, and 145 Series. It supports both gastrointestinal endoscopy and bronchoscopy.

If you have a separate spec sheet naming an actual CV-165/CLV-165 processor, I'd need to see it — this brochure only documents the scopes and their compatibility with the 160/145/140 processor generation.


Champ de vision :
140°
Direction de visée :
vision frontale
Profondeur de champ :
3 à 100 mm
  • Olympus GIF Type Q165 — Gastrointestinal Videoscope (upper GI), 9.2 mm diameter, 140° field of view
  • Olympus CF Type Q165L/I — Colonovideoscope, 12.8 mm diameter, 140° field of view
  • CV-160
  • CV-145
  • CV-140
  • Q165/Q145 Series — Gastrointestinal videoscopes
  • Q160 Series — Bronchovideoscopes