Phone: (+33) 625 16 20 71 - Sunday to Friday contact@alliancemedicalfrance.fr

Olympus Vidéo-gastroscope ultrasonique GF-UCT140-AL5

Olympus

Vidéo-gastroscope ultrasonique GF-UCT140-AL5

Starting from
20 445 .00 €

Olympus GF-UCT140-AL5 ultrasonic gastrovideoscope with a 3.7 mm channel, 100° optical field of view and 180° ultrasound scanning for EUS-guided diagnostic and therapeutic procedures.

OLYMPUS GF-UCT140-AL5 – EUS/EBUS Ultrasound Endoscope

The OLYMPUS GF-UCT140-AL5 is an EUS/EBUS ultrasound endoscope designed for ultrasound-guided diagnostic and therapeutic procedures. It combines Olympus endoscopic imaging with advanced ultrasound imaging technology, providing precise visualization and flexibility during interventions.

Advanced Ultrasound Imaging

The GF-UCT140-AL5 uses an electronic convex-array scanning transducer for high-resolution ultrasound imaging. It supports technologies such as Color Doppler and Power Doppler, helping assess vascular structures and blood flow around the area being examined.

  • Transducer: Electronic convex-array scanning transducer.
  • Color Doppler: Yes.
  • Power Doppler: Yes.
  • Focusing: Electronically adjustable.
  • Imaging: Multifrequency.
  • Scanning angle: 180°.

Design and Maneuverability

The GF-UCT140-AL5 is designed to facilitate insertion and improve maneuverability during procedures. The convex-array transducer design helps provide access to the area of interest, while the wide scanning angle allows extensive observation of surrounding structures.

Olympus' patented forceps elevator also enables precise adjustment of the needle position after the endoscope has been stabilized, particularly during FNA (Fine Needle Aspiration) procedures.

Instrument Channel

The GF-UCT140-AL5 features a 3.7 mm instrument channel. This diameter allows the use of suitable aspiration needles and therapeutic accessories, providing greater flexibility for diagnostic and interventional procedures.

Clinical Applications

The ultrasound endoscope is intended for various ultrasound-guided diagnostic and interventional applications, including:

  • Fine Needle Aspiration (FNA) of pancreatic cysts.
  • Assessment and intervention involving gastric varices.
  • Evaluation of pancreatic pseudocysts.
  • Assessment of subcarinal lymph nodes.
  • Pancreatic cyst drainage.
  • Imaging and evaluation of gallbladder cancers.

Key Specifications

  • Model: OLYMPUS GF-UCT140-AL5
  • Type: EUS/EBUS ultrasound endoscope
  • Transducer: Electronic convex-array scanning transducer
  • Instrument channel: 3.7 mm
  • Scanning angle: 180°
  • Color Doppler: Yes
  • Power Doppler: Yes
  • Multifrequency imaging: Yes
  • Condition: Excellent
  • Warranty: Yes
Quick delivery worldwide
All our equipment is rigorously tested to ensure its quality and compliance with safety standards.
Download brochure

OLYMPUS GF-UCT140-AL5 – EUS/EBUS Ultrasound Endoscope

The OLYMPUS GF-UCT140-AL5 is an EUS/EBUS ultrasound endoscope designed for ultrasound-guided diagnostic and therapeutic procedures. It combines Olympus endoscopic imaging with advanced ultrasound imaging technology, providing precise visualization and flexibility during interventions.

Advanced Ultrasound Imaging

The GF-UCT140-AL5 uses an electronic convex-array scanning transducer for high-resolution ultrasound imaging. It supports technologies such as Color Doppler and Power Doppler, helping assess vascular structures and blood flow around the area being examined.

  • Transducer: Electronic convex-array scanning transducer.
  • Color Doppler: Yes.
  • Power Doppler: Yes.
  • Focusing: Electronically adjustable.
  • Imaging: Multifrequency.
  • Scanning angle: 180°.

Design and Maneuverability

The GF-UCT140-AL5 is designed to facilitate insertion and improve maneuverability during procedures. The convex-array transducer design helps provide access to the area of interest, while the wide scanning angle allows extensive observation of surrounding structures.

Olympus' patented forceps elevator also enables precise adjustment of the needle position after the endoscope has been stabilized, particularly during FNA (Fine Needle Aspiration) procedures.

Instrument Channel

The GF-UCT140-AL5 features a 3.7 mm instrument channel. This diameter allows the use of suitable aspiration needles and therapeutic accessories, providing greater flexibility for diagnostic and interventional procedures.

Clinical Applications

The ultrasound endoscope is intended for various ultrasound-guided diagnostic and interventional applications, including:

  • Fine Needle Aspiration (FNA) of pancreatic cysts.
  • Assessment and intervention involving gastric varices.
  • Evaluation of pancreatic pseudocysts.
  • Assessment of subcarinal lymph nodes.
  • Pancreatic cyst drainage.
  • Imaging and evaluation of gallbladder cancers.

Key Specifications

  • Model: OLYMPUS GF-UCT140-AL5
  • Type: EUS/EBUS ultrasound endoscope
  • Transducer: Electronic convex-array scanning transducer
  • Instrument channel: 3.7 mm
  • Scanning angle: 180°
  • Color Doppler: Yes
  • Power Doppler: Yes
  • Multifrequency imaging: Yes
  • Condition: Excellent
  • Warranty: Yes
  • High-Resolution Imaging: High-resolution CCD provides clear and detailed endoscopic images.
  • Advanced Imaging Technologies: Color Doppler and Power Doppler facilitate the assessment of blood flow.
  • Electronic Focusing: Enables electronic focus adjustment and multi-frequency imaging.
  • Enhanced Maneuverability: The convex array transducer features a reduced radius for easier insertion.
  • Wide Scanning Angle: A 180° scanning angle enables extensive visualization of surrounding structures.
  • Forceps Elevator Design: Allows precise adjustment of the needle position to facilitate accurate placement during FNA procedures.
Canal d'InstrumentDiamètre intérieur du canal :
3,7 mmDistance visible minimale : 8 mm
Tube d'InsertionDiamètre extérieur de l'extrémité distale :
14,6 mmDiamètre extérieur du tube d'insertion : 12,6 mmLongueur de travail : 1250 mm
Système OptiqueChamp de vision :
100°Direction de vue : 50° oblique avantProfondeur de champ : 3 à 100 mm
Section de CourburePlage d'angulation :
Haut 130°, Bas 60°, Droite 30°, Gauche 50°
  • NA-200H-8022 – Single-use aspiration needle
  • NA-11J-KB – Aspiration needle
  • MAJ-1443 – Single-use air/water valve
  • MAJ-1444 – Single-use air/water valve
Scroll