Olympus VISERA CLV-S40 xenon light source designed for endoscopy, providing reliable illumination with automatic or manual brightness control and an emergency lamp for continued observation.
The OLYMPUS CLV-S40 is a light source designed to provide powerful and stable illumination during endoscopic procedures. Equipped with a 300 W electrodeless xenon lamp, it delivers consistent lighting suitable for detailed observation of the examination site.
Light intensity can be adjusted automatically or manually to suit different examination conditions. When connected to a compatible video system, the automatic brightness control allows the illumination level to be adjusted quickly according to the requirements of the procedure.
The CLV-S40 can be integrated into various endoscopic configurations and used with conventional telescopes, fiberscopes, and compatible VISERA videoscopes. The MAJ-1200 universal light guide adapter also allows connection to certain non-Olympus light guide cables.
To maintain illumination in the event of failure of the main lamp, the CLV-S40 is equipped with a 24 V / 150 W halogen emergency lamp. Front-panel indicators allow users to monitor the status of the emergency lamp and the selected operating modes.
With its 300 W xenon lamp, adjustable light intensity, and emergency lighting system, the OLYMPUS CLV-S40 provides a versatile solution for a range of endoscopic configurations.
The OLYMPUS CLV-S40 is a light source designed to provide powerful and stable illumination during endoscopic procedures. Equipped with a 300 W electrodeless xenon lamp, it delivers consistent lighting suitable for detailed observation of the examination site.
Light intensity can be adjusted automatically or manually to suit different examination conditions. When connected to a compatible video system, the automatic brightness control allows the illumination level to be adjusted quickly according to the requirements of the procedure.
The CLV-S40 can be integrated into various endoscopic configurations and used with conventional telescopes, fiberscopes, and compatible VISERA videoscopes. The MAJ-1200 universal light guide adapter also allows connection to certain non-Olympus light guide cables.
To maintain illumination in the event of failure of the main lamp, the CLV-S40 is equipped with a 24 V / 150 W halogen emergency lamp. Front-panel indicators allow users to monitor the status of the emergency lamp and the selected operating modes.
With its 300 W xenon lamp, adjustable light intensity, and emergency lighting system, the OLYMPUS CLV-S40 provides a versatile solution for a range of endoscopic configurations.